Maretron RAA100 Installationsanleitung Seite 49

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 82
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 48
Copyright 2009 Maretron, LLP. All rights reserved. As Maretron is constantly improving its products, all specifications are subject to change without notice. Maretron’s products are designed to
be accurate and reliable; however, they should be used only as aids to navigation and vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. A
prudent captain or navigator never relies on a single source for navigation or system monitoring information. “NMEA 2000” is a registered trademark of the National Marine Electronics Association.
49
DSM250 Screen Shots
Environmental Mechanical Electrical
Specifications
NMEA 2000
®
Parameter
Group Numbers (PGNs)
Certifications
Description PGN # PGN Name Default Rate
Periodic Data PGNs 127505 Fluid Level
0.4 times/second
Response to Requested
PGNs
126464 PGN List (Transmit and Receive)
N/A
126996 Product Information
N/A
126998
Configuration Information
N/A
Protocol PGNs
059392
ISO Acknowledge
N/A
059904 ISO Request
N/A
060928
ISO Address Claim
N/A
065240
ISO Address Command
N/A
126208 NMEA
N/A
Parameter Value Comment
Operating Voltage 9 to 16 Volts DC Voltage
Power Consumption <100mA Average Current Drain
Load Equivalence Number (LEN) 2 NMEA 2000® Spec. (1LEN = 50mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113
Parameter Value Comment
Accuracy +/-2%
Resolution +/-1%
Number of Tank Types 16
Fuel, Fresh Water, Waste Water, Live well, Oil, etc.
Number of Tanks per Tank Type 16
16 Tanks per Tank Type Numbered 0-15
Maximum Tank Depth 40” (1.02m)
Minimum Depth Reading 2” (5.08cm)
Sensor Deadband
Support for Irregularly Shaped Tanks Yes
Can be Calibrated for any Shape Tank
Programmable Tank Capacity Yes
Allows Displays to Calculate Amount Remaining
Maximum Tank Angle
Without focus tube
15°
With focus tube
Parameter Value
IEC 60945 Classification Exposed
Degree of Protection IP67
Operating Temperature -25°C to 55°C
Storage Temperature -40°C to 70°C
Relative Humidity 93%RH @40° per IEC60945-8.2
Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7
Rain and Spray
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Solar Radiation Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist) 4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission Conducted and Radiated Emission per IEC 60945-9
Electromagnetic Immunity Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Standard Comment
NMEA 2000 Level B
Maritime Navigation and Radio Communication Equipment & Systems Tested to IEC 60945
FCC and CE mark Electromagnetic Compatibility
Parameter Value Comment
Size
3.9” x 1.2” x 1.0” (99mm x 30.5mm x 25.4mm) Interface Component
2.7” dia. X 0.9” (68.6mm dia. x 22.9mm) Sensor Component
8.5” (215.9mm) Interconnecting Cable
Weight 12 oz. (340g)
Mounting
SAE J1810 5-hole bolt pattern
Can mount to 1.25” BSP or 1.5” NPT using
available adapters
Seitenansicht 48