Maretron SIM100 Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
SIM100 User's Manual
SIM100 Screw Terminals
Monitored switch
1 2 5 4 3 6 7 8 9 10 11 12
SW1A
SW2B
SW1B
SW2A
SW3A
SW3B
SW4A
SW4B
SW5A
SW5B
SW6A
SW6B
Figure 4 – Switch Without End of Line Resistor Connection Diagram
2.4.3 Checking Connections
Once the NMEA 2000
®
connection and switch connection(s) to the SIM100 have been
completed, check to see that information is being properly transmitted by observing an
appropriate NMEA 2000
®
display. If you don’t see switch indicator status, refer to Section 4,
“Troubleshooting”.
2.5 Configuring the SIM100
The SIM100 will transmit data over the NMEA 2000 network as it is shipped from the factory;
however, it may require configuration, depending on the type of switch monitored. There are
several configurable items within the SIM100, which are detailed in the remainder of this
section.
You configure the SIM100 using a Maretron DSM250 display or other NMEA 2000
®
display
unit that is capable of configuring the SIM100. Please refer to the Maretron DSM250 User’s
Manual for details.
2.5.1 Device Instance
NMEA 2000
®
provides a unique device instance for each switch monitoring device on a vessel.
This value should be programmed in each SIM100 so that each SIM100 is associated with a
unique device instance number. The default instance number is 0, which is used to indicate the
first SIM100 that is hooked to the network. Subsequent SIM100s connected to the network
would be numbered 1, 2, and so on.