SIM100 User's Manual
Page 8 Revision 1.2
Check the security of the cable connected to the NMEA 2000
®
connector, and tighten if
necessary.
Check the security of all of the switch connections on the top of the unit and tighten if
necessary.
4 Troubleshooting
If you notice unexpected operation of the Maretron SIM100, follow the troubleshooting
procedures in this section to remedy simple problems. If these steps do not solve your
problem, please contact Maretron Technical Support (refer to Section 6 for contact
information).
Symptom Troubleshooting Procedure
No switch indicator data
visible on NMEA 2000
®
network.
Ensure that the SIM100 is properly connected to the NMEA 2000
®
network.
Ensure that the switches are properly connected to the SIM100.
Ensure that each indicator that you wish to monitor is not
configured as “Disabled”.
Ensure that the SIM100 has the appropriate NMEA 2000
®
PGNs
enabled as described in Section 2.5.9.
A switch indicator
always reads “Closed”
Ensure that there is not a short circuit in the wiring for the switch.
Measure the resistance between the “A” and “B” terminals for the
appropriate indicator. If the switch is open, the resistance should
either be an open-circuit, if the indicator is configured as “No End
of Line Resistor”, or should measure 8 K if the indicator is
configured as “End of Line Resistor”. If the switch is closed, the
resistance should be close to 0 .
A switch indicator
always reads “Error”
Ensure that the configuration of the indicator matches the circuit
connected to it. Measure the resistance between the “A” and “B”
terminals for the appropriate indicator. If the switch is open, the
resistance should either be an open-circuit, if the indicator is
configured as “No End of Line Resistor”, or should measure 8 K if
the indicator is configured as “End of Line Resistor”. If the switch
is closed, the resistance should be close to 0 .
A switch indicator
always reads “Open”
Ensure that the switch is connected to the indicator terminals that
that there are no open circuits between the SIM100 and the switch.
Measure the resistance between the “A” and “B” terminals for the
appropriate indicator. If the switch is open, the resistance should
either be an open-circuit, if the indicator is configured as “No End
of Line Resistor”, or should measure 8 K if the indicator is
configured as “End of Line Resistor”. If the switch is closed, the
resistance should be close to 0 .