Seitenansicht 250
being the most important. N2KView will ensure that every alert has a unique
priority number by omitting used priorities from the drop down list. You can have
an Alarm and a Warning with the same Priority. Implicitly, all Alarms have a
higher Priority than all Warnings. (i.e. Alarm 567 has a higher Priority than
Warning 0.)
10.3.6.1.3 Scope
This field allows you to determine whether the alert will appear only on the
instance of N2KView where it is defined (Local) or on all instances of N2KView
on the network with an Alerts License (Global).
10.3.6.1.4 Description
You may type here a text description of the alert. This Description will be
displayed on the Alarm Status Bar as a label for the alert, and will also appear in
the description column on the Alerts Screen. This field must be filled in.
10.3.6.1.5 Location
You may type here a location of the alert. This location will be displayed on the
Alarm Status Bar as part of the label for the alert, and will also appear in the
“Location” column on the Alerts Screen. This field is optional.