Figure 99Trigger Configuration - GPS Quality Alert
Accept Re-trigger PeriodWhen you accept an alert, it will change to the
“Accepted” state, and annunciators that are sounding for that alert will stop
sounding. If the condition which caused the alert remains true after the amount of
time in this field, the alert will return to the “Active” state, and annunciators will
begin sounding again for that alert.
If a value of 0:00 is entered, then the alert will never re-trigger.
GPS Quality Alert Set Point, Set DelayWhen the quality of the GPS fix
becomes lower than the quality specified in this field for longer than the time
specified in the Set Delay field, the alert will become active.
GPS Quality Alert Set Point, Clear DelayIf the alert is active and the quality
of the GPS fix becomes higher than the quality specified in the GPS Quality Alert
Set Point field for longer than the time specified in the Clear Delay field, the alert
will become inactive.
10.3.6.4.12 Direction Alert
A Direction Alert is used to indicate that a heading or wind direction has changed
from the reference direction more than a programmable amount. For example,
once a heading has been established, an alert can be generated if the heading