10.4.10.11 Outside Temperature
Monitors the temperature from a temperature sensor set up with a source of
“outside”.
Alert Types: Low Alert, High Alert, Data Unavailable Alert
Instances: 253
10.4.10.12 Sea Temperature
Monitors the temperature from a temperature sensor set up with a source of
“Sea”.
Alert Types: Low Alert, High Alert, Data Unavailable Alert
Instances: 253
10.4.10.13 User Defined nnn Humidity
Monitors the relative humidity from a humidity sensor set up with a source of
“User Defined nnn”, where nnn is a number from 128 to 144.
Alert Types: Low Alert, High Alert, Data Unavailable Alert
Instances: 253
10.4.10.14 User Defined nnn Temperature
Monitors the temperature from a temperature sensor set up with a source of
“User Defined nnn” , where nnn is a number from 128 to 144..
Alert Types: Low Alert, High Alert, Data Unavailable Alert
Instances: 253
10.4.10.15 Wind Chill
Monitors the current wind chill based on outside air temperature and wind speed
Alert Types: Low Alert, High Alert, Data Unavailable Alert
Revision 4.0.2 Page 317