Enable Computer Sound This check box can be used to disable this
computer’s sound for this Alert. It does not disable the sounds generated by
remote N2KView stations or DSM250s in response to this Alert.
ToneN2KView supports the presence of up to sixteen different annunciators
on the vessel. All annunciators must sound with the same tone, which is selected
from a drop-down list.
Figure 104Annunciator Tone Selection
Annunciators - For each alert, you may choose which annunciators sound the
selected tone. For example, you may wish the annunciator in the owner’s
stateroom to sound in the event of a general emergency or if smoke is detected,
but not if the engine coolant temperature is too high. If the annunciator has been
programmed with a label, N2KView will get the label from the annunciator and
append the label to the instance number. This makes it easier to know which
annunciator is being referenced.
10.3.7.2 Switch Actions Tab
The switch actions tab has been removed for safety reasons.
If the optional Control Module for N2KView has been licensed, it will be possible
to command breakers on the NMEA2000 bus to switch on or off in response to a
change of state of an alert.
The Switch Actions Tab for the Alert Actions Dialog is shown below.