11.1.3 Visual Indication Stage
If there is no input to N2KView for the entire dormant period, the BNWAS will
enter the Visual Indication stage. In the visual indication stage a yellow warning
will show at the bottom of the N2KView screen.
The visual indication stage will last 15 seconds. Any key press, mouse click, or
touch on the N2KView screen during the visual indication stage will reset the
BNWAS to the start of the dormant period and the yellow warning will be
removed.
11.1.4 First Stage Bridge Audible Alarm
If there is no input to N2KView during the visual indication stage, the BNWAS will
enter the First Stage Bridge Audible Alarm. The yellow warning is changed to a
red Alarm at the bottom of the screen, and an ALM100 annunciator on the bridge
will alert the watchkeeper.
The instance number of the ALM100 on the bridge, and the required tone are
configured in the First Stage Bridge Audible Alarm Annunciator and First
Stage Bridge Audible Alarm Tone fields in the dialog.
The First Stage Bridge Audible Alarm stage will last 15 seconds.
11.1.5 Second Stage Remote Audible Alarm
If there is no input to N2KView during the First Stage Bridge Audible Alarm, the
BNWAS will enter the Second Stage Remote Audible Alarm. A second ALM100
annunciator elsewhere on the vessel will sound to summon another person to the
bridge.
The instance number of the second ALM100 and the required tone are
configured in the Second Stage Remote Audible Alarm Annunciator and
Second Stage Remote Audible Alarm Tone fields in the dialog.
11.1.6 Third Stage Remote Audible Alarm
If there is no input to N2KView during the Second Stage Bridge Audible Alarm,
the BNWAS will enter the Third Stage Remote Audible Alarm. A third ALM100
annunciator elsewhere on the vessel will sound to summon yet another person to
the bridge.
The instance number of the third ALM100 and the required tone are configured in
the Third stage Remote Audible Alarm Annunciator and Third Stage Remote
Audible Alarm Tone fields in the dialog.